RAID Calculator: Usable Capacity and Drives Needed

Work out the usable capacity of a RAID 0, 1, 5, 6, 10, 50 or 60 array, or enter the capacity you need and get the number of drives. Results assume identical drives and are shown in decimal TB (as drives are sold) and binary TiB (as most operating systems report space), before filesystem overhead.

Example: 200TB usable in RAID 6

  • 11 × 24TB in RAID 6 = 216TB usable (196.45 TiB), 82% of raw capacity; survives 2 drive failures.
  • 200TB usable from 24TB drives in RAID 6 takes 11 drives (216TB usable).

Identical drives; decimal TB as drives are sold, binary TiB as most operating systems show it; before filesystem overhead. Hot spares are extra drives and add no capacity.

RAID levels compared

LevelUsable capacityMinimum drivesDrive failures survivedDisk I/Os per random write
RAID 0n × S2None1
RAID 1S2n − 12
RAID 5(n − 1) × S314
RAID 6(n − 2) × S426
RAID 10(n ÷ 2) × S41 (up to 1 per mirrored pair)2
RAID 50(n − g) × S61 (up to 1 per group)4
RAID 60(n − 2g) × S82 (up to 2 per group)6

n = drives in the array, S = drive size, g = number of RAID 5 or RAID 6 groups.

Drives needed with 24TB drives

Usable targetRAID 5RAID 6RAID 10RAID 60
50TB4 drives (72TB)5 drives (72TB)6 drives (72TB)8 drives (96TB)
100TB6 drives (120TB)7 drives (120TB)10 drives (120TB)10 drives (144TB)
200TB10 drives (216TB)11 drives (216TB)18 drives (216TB)14 drives (240TB)
500TB22 drives (504TB)23 drives (504TB)42 drives (504TB)26 drives (528TB)

RAID 60 shown with 2 groups. Hot spares not included.

How usable capacity is calculated

Every level gives up some raw capacity for redundancy. With n identical drives of size S:

RAID 0: n × S, no redundancy. RAID 1: S, every drive holds a full copy. RAID 5: (n − 1) × S, one drive of parity. RAID 6: (n − 2) × S, two drives of parity. RAID 10: (n ÷ 2) × S, mirrored pairs. RAID 50: (n − g) × S and RAID 60: (n − 2g) × S, where g is the number of RAID 5 or RAID 6 groups striped together.

Why the operating system shows less than the label

Drive makers count in decimal: a 24TB drive holds 24 × 10¹² bytes. Most operating systems count in binary units, so the same drive appears as 21.83 TiB. Nothing is missing; it is the same number of bytes in a different unit. The filesystem then reserves some space for its own metadata, which is why the calculator reports capacity before filesystem overhead.

Hot spares

A hot spare is an installed drive that sits idle until another drive fails, then the controller rebuilds onto it automatically. It adds no capacity, so the calculator counts spares on top of the drives in the array.

Mixed drive sizes

Traditional RAID treats every drive as the size of the smallest drive in the array; the extra space on larger drives goes unused. Plan arrays with drives of the same capacity.

24TB drives for this array

In-stock 24TB drives from our catalogue, with the price for the 11 drives in the example above. Hot spares are extra.

Frequently asked questions

How many 24TB drives do I need for 200TB usable in RAID 6?

11 drives. RAID 6 uses two drives' worth of capacity for parity, so 11 × 24TB gives 9 × 24TB = 216TB usable (196.45 TiB), before filesystem overhead. Add any hot spares on top.

What is the usable capacity of RAID 5 with 4 × 8TB drives?

24TB (21.83 TiB). RAID 5 keeps (n − 1) drives of data: 3 × 8TB. The array survives one drive failure.

Does a hot spare add capacity?

No. A hot spare is idle until a drive fails, then the array rebuilds onto it. Count it in the drives you buy, not in usable capacity.

Why does my array show less space than the calculator?

Two reasons. The operating system usually shows binary TiB rather than the decimal TB drives are sold in (24TB appears as 21.83 TiB), and the filesystem and RAID controller reserve a small amount of space for their own metadata.

Does this calculator work for Synology, QNAP or ZFS?

For standard RAID 0, 1, 5, 6 and 10 on any NAS or server controller, yes: the capacity math is the same. Synology Hybrid RAID (SHR) and ZFS RAID-Z are calculated differently (SHR can use mixed drive sizes; RAID-Z adds allocation overhead that depends on the pool layout), so use the vendor’s own tool for those.

How many drives can fail in RAID 5, 6 and 10?