RAID 5 Calculator

RAID 5 stripes data with one drive's worth of distributed parity. It survives one drive failure and keeps the most capacity of any redundant level.

RAID 5 at a glance

  • 8 × 16TB in RAID 5 = 112TB usable (101.86 TiB), 88% of raw capacity; survives 1 drive failure.
  • 100TB usable from 16TB drives in RAID 5 takes 8 drives (112TB usable).

Identical drives; decimal TB as drives are sold, binary TiB as most operating systems show it; before filesystem overhead. Hot spares are extra drives and add no capacity.

RAID 5 usable capacity by drive count

Drives1.92TB3.84TB8TB12TB16TB24TB
33.84TB7.68TB16TB24TB32TB48TB
45.76TB11.52TB24TB36TB48TB72TB
57.68TB15.36TB32TB48TB64TB96TB
69.6TB19.2TB40TB60TB80TB120TB
813.44TB26.88TB56TB84TB112TB168TB
1017.28TB34.56TB72TB108TB144TB216TB
1221.12TB42.24TB88TB132TB176TB264TB

Usable capacity in decimal TB, before filesystem overhead. — means the drive count is not valid for RAID 5.

RAID 5 formula

Usable capacity = (n − 1) × S. Minimum 3 drives. Fault tolerance: 1 drive. Example: 4 × 8TB = 24TB (21.83 TiB), 75% of raw capacity.

Rebuilds on large drives

After a failure, the controller reads every remaining drive in full to rebuild the lost one. Until that finishes, the array has no redundancy: a second failure, or an unreadable sector on another drive, can lose data. Larger drives take longer to rebuild, which is why many administrators choose RAID 6 for large nearline drives.

Write cost

Each random write costs four disk operations (read data, read parity, write data, write parity). RAID 5 suits read-heavy workloads better than heavy random writes.

16TB drives for this array

In-stock 16TB drives from our catalogue, with the price for the 8 drives in the example above. Hot spares are extra.

Frequently asked questions

How many 16TB drives do I need for 100TB usable in RAID 5?

8 drives, giving 7 × 16TB = 112TB (101.86 TiB), before filesystem overhead.

What is the minimum number of drives for RAID 5?

Three: two drives of data plus one of parity.

Should I use RAID 5 or RAID 6?

RAID 6 gives up one more drive of capacity to survive two failures, which also covers a second failure during a rebuild. For large drives, RAID 6 is the safer default.

How many drives can fail in RAID 5?

One. A second failure before the rebuild finishes loses the array.

RAID calculators by level

RAID planning guides

Related

Updated 2026-10-22.

Part of

Enterprise Storage Hub

View all 172 pages →

Enterprise HDDs, SSDs, NVMe, SAS, SATA, RAID controllers, drive caddies and storage array hardware.