RAID 60 Calculator

RAID 60 stripes data across two or more RAID 6 groups. Each group gives two drives to parity and survives two failures of its own, which suits large arrays of high-capacity drives.

RAID 60 at a glance

  • 14 × 24TB in RAID 60 = 240TB usable (218.28 TiB), 71% of raw capacity; survives at least 2 drive failures, up to 4 if each is in a different group.
  • 200TB usable from 24TB drives in RAID 60 takes 14 drives (240TB usable).

Identical drives; decimal TB as drives are sold, binary TiB as most operating systems show it; before filesystem overhead. Hot spares are extra drives and add no capacity.

RAID 60 usable capacity by drive count

Drives1.92TB3.84TB8TB12TB16TB24TB
8 (2 groups)7.68TB15.36TB32TB48TB64TB96TB
10 (2 groups)11.52TB23.04TB48TB72TB96TB144TB
12 (2 groups)15.36TB30.72TB64TB96TB128TB192TB
16 (2 groups)23.04TB46.08TB96TB144TB192TB288TB
20 (2 groups)30.72TB61.44TB128TB192TB256TB384TB
24 (2 groups)38.4TB76.8TB160TB240TB320TB480TB

Usable capacity in decimal TB, before filesystem overhead. — means the drive count is not valid for RAID 60.

RAID 60 formula

Usable capacity = (n − 2g) × S, where g is the number of RAID 6 groups (at least 2, each with at least 4 drives and the same drive count). Minimum 8 drives. Example: 24 × 20TB in 2 groups = 400TB (363.8 TiB).

Fault tolerance

Two drives per group are guaranteed: the array survives any 2 failures, and up to 2 × g if they are spread across groups. Three failures in the same group lose the array.

When to choose RAID 60

Large shelves of nearline drives for backup, archive and video, where one RAID 6 group would be too wide to rebuild quickly. Splitting into groups keeps each rebuild smaller.

24TB drives for this array

In-stock 24TB drives from our catalogue, with the price for the 14 drives in the example above. Hot spares are extra.

Frequently asked questions

How many 24TB drives do I need for 200TB usable in RAID 60?

14 drives in 2 groups of 7: 240TB usable (218.28 TiB), before filesystem overhead. The same target takes 11 drives in a single RAID 6 group.

What is the usable capacity of 24 × 20TB drives in RAID 60?

400TB with 2 groups of 12: 20 drives of data, 4 of parity.

What is the minimum number of drives for RAID 60?

Eight: two RAID 6 groups of four drives each.

How many drives can fail in RAID 60?

At least two, and up to two per RAID 6 group, as long as no group loses three drives.