Rackmount UPS Battery Backup - APC, Eaton, Tripp Lite

1U / 2U / 3U rackmount UPS units with replaceable battery cartridges

About Rackmount UPS Battery Backup

Power-protection in the rack is non-negotiable. Pro Disk Network stocks APC Smart-UPS SRT, Eaton 9PX / 9SX, Tripp Lite SmartOnline, and Vertiv Liebert GXT rackmount UPS units in 1U, 2U, and 3U form factors with capacity from 1500VA up to 10kVA.

All units carry double-conversion (online) topology with sine-wave output, replaceable battery cartridges, and SNMP/network management cards available factory-installed or as add-ons. We also stock replacement battery cartridges (RBC) for end-of-life units that just need new batteries, not a whole new UPS.

Picking the Right Capacity

Load TypeTypical UPS
1U server (1x 750W PSU)1500VA / 980W (Smart-UPS SMT1500RM)
2U server (2x 750W PSU)2200VA / 1980W (Smart-UPS SMT2200RM2U)
4-server 1U cluster3000VA / 2700W (Smart-UPS SMT3000RM2U)
Full half-rack (10kW)10kVA / 9kW (SRT10KRMXLI, Eaton 9PX 11kVA)

Pair every UPS with its matching C19/C20 power cabling for the connected loads (we stock the IEC cables too). For multi-rack deployments we offer engineered runtime analysis - send us your rack load list and target runtime and we will spec the right UPS+battery-extension combination.

Featured Rackmount UPS Battery Backup Products

Browse all 224 Rackmount UPS Battery Backup SKUs.

Frequently Asked Questions

What is the difference between line-interactive and double-conversion UPS?

Line-interactive (APC Smart-UPS SMT) regulates voltage but switches to battery only when input fails - good for office and edge sites. Double-conversion / online (APC SRT, Eaton 9PX, Tripp Lite SmartOnline) continuously converts AC-DC-AC, isolating the load from all power anomalies - required for data centers, sensitive servers, and medical/industrial equipment.

How long will a 2200VA rackmount UPS run a 2U server?

A typical 2U server drawing ~400-500W will get 18-25 minutes of runtime from a fully-charged APC Smart-UPS SMT2200RM2U. Adding one external battery pack (BR48V31RM2U) extends that to ~50-70 minutes. For longer runtimes, add additional battery cabinets - APC supports up to 10 packs in series.

Do these UPS units include the rack rails?

New APC, Eaton, and Tripp Lite rackmount UPS units ship with their factory rail kit. Refurbished units may or may not - we list the included accessories on each product page. If rails are missing we can source matching OEM rails separately.

Can these UPS units send shutdown signals to my servers?

Yes. APC ships with PowerChute software (Windows / Linux / VMware); Eaton uses Intelligent Power Manager (IPM); Tripp Lite uses PowerAlert. All major UPS brands support SNMP via an optional network management card (we stock these), which integrates with iDRAC, iLO, vCenter, and any standard monitoring platform.